- 406 MHz
- 5 W digital burst about every 50 seconds. Carries the beacon's unique ID, and its GNSS position when it has a fix.
- 121.5 MHz
- Low-power homing signal. Aircraft and ships use it to find the beacon in the final stage of the search.
- Strobe
- High-intensity white light flashing 20–30 times a minute to help searchers see the beacon at night.
- Battery
- At least 48 hours of operation. Replace by the expiry date on the label.
- HRU
- Hydrostatic release unit. Frees the EPIRB at 1.5–4 m depth so it floats up and activates. Usually replaced every 2 years.
- Category I / II
- Cat I is float-free and activates automatically. Cat II is manual only.
- Testing
- Self-test monthly, annual test, and shore-based maintenance at intervals of no more than 5 years.
- Registration
- Register the beacon with the national authority. The RCC uses it to identify the vessel and call its emergency contacts.
- False alert
- Switch the beacon off and immediately tell the nearest RCC or coast station. Never just switch off and say nothing. Ships nearby will also have seen EPIRB ACTIVE on their AIS.
- AIS test
- The self-test sends a short AIS test message: your own AIS shows EPIRB TEST, not a distress alarm.